English

Home › Family › 48V 250Ah Forklift Battery

Forklift family — model system page

48V 250Ah Forklift Battery

An industrial 48V 250Ah lithium iron phosphate power battery built around machine integration: its equipment context is a pair of 2kW motors with controller and PLC, its CAN protocol is provided for PLC reading, and its state-of-charge accuracy is ≤5%. Maximum discharge is 100A against a 4kW maximum load, with an IP53 rating.

Illustration of a forklift lifting a battery unit

Key data — 48V 250Ah Forklift Battery

Nominal voltage / capacity48V / 250Ah
CellsAL50 3.2V 50Ah LiFePO4, 16S5P (80 cells)
Maximum discharge100A
Charge50A standard / 100A maximum
Maximum load4kW
Internal resistance≤80mΩ
CommunicationCAN protocol, provided for PLC reading
SOC accuracy≤5%
Equipment context2 × 2kW motors + controller, PLC
Cycle life≥2000 cycles (0.5C / 1C, 80% DOD)
RatingIP53
Dimensions / weight170×500×800/850mm / ≈115kg

48V 250Ah ratings in full

Maximum discharge is 100A against a 4kW maximum load. Charge is 50A standard and 100A maximum. Cycle life is ≥2000 cycles at 0.5C charge / 1C discharge and 80% depth of discharge. The unit measures 170×500×800/850mm at about 115kg and carries an IP53 rating.

The 48V 250Ah specification

The cell build is the first thing to read correctly: AL50 3.2V 50Ah cells in 16S5P — sixteen series groups of five parallel 50Ah cells, which is 80 cells in total, not a small-cell build of over a thousand. Five 50Ah cells in parallel give each group 250Ah, and sixteen groups in series give the 48V class. Large-format cells mean fewer interconnects and a simpler current path, which is part of how the unit holds ≤80mΩ internal resistance. The discharge specification is a single ceiling — 100A maximum — rather than a continuous/peak pair, and the load ceiling is 4kW; machine builders should size against those two numbers as they stand. Charge is 50A standard and 100A maximum, so a full recharge runs from about five hours at the standard rate to about two and a half at the maximum. The cycle rating's conditions come with it — 0.5C / 1C, 80% depth of discharge — which is what makes the ≥2000 figure comparable against other quotes.

Built to be read by a PLC

This is the family's machine-integration battery. It was specified around a clear equipment context — two 2kW motors with a controller and a PLC — and states that the CAN protocol is provided for PLC reading: the machine's controller reads the battery's data over CAN rather than estimating charge from voltage. The figure that makes that reading trustworthy stands beside it: SOC accuracy of ≤5%. At 250Ah, a 5% band is 12.5Ah — small against a shift's throughput, and small enough for a PLC to schedule charge windows and low-battery behaviour from the battery's own report. The model comes with a BMS section setting out the management system's electrical schematic, so the integration conversation starts from the manufacturer's own diagram rather than from a sales summary. Enquiries for this model should name the PLC or controller family and the data set the machine needs; the protocol documentation is part of the model's offer.

Charging the 250Ah system

The charge pair — 50A standard, 100A maximum — sizes the depot: about five hours for a full charge at the standard rate, about two and a half at the maximum, which puts a mid-shift opportunity charge inside a long break. This system has no matched charger of its own, and the 54.0V 18A matched unit in this range belongs to the 48V 40Ah AGV battery; charger selection for this system is made at enquiry against the charge pair and the machine's shift pattern. The IP53 rating belongs in the same conversation: the unit is specified for splashed, dusty industrial environments, and the charge point's placement should respect the rating rather than test it.

Integrating and commissioning the 250Ah unit

The envelope converts to roughly 6.7 × 19.7 × 31.5/33.5 inches and the mass to about 254 lb — a two-person or assisted lift, into a machine compartment rather than a truck's counterweight slot. Integration runs: compartment fit against the envelope; cable and connector sizing against the 100A discharge ceiling; the CAN connection to the machine's PLC, with the protocol document in the project file before the first power-up; and a commissioning discharge under the machine's real duty, logged against the SOC the battery reports — the ≤5% accuracy claim is checkable on day one, and the commissioning record is where a fleet proves it. Maintenance is the industrial pattern: terminal and connector inspection on the machine's own service calendar, SOC drift checked against the commissioning baseline, and cycle counting from the machine's logs against the ≥2000 rating.

Worked example: a PLC-controlled handling machine

Take a handling machine built on the equipment pattern: two 2kW drive motors under a controller and PLC, working two shifts with a one-hour mid-day break. Load check first: the motors' combined 4kW sits exactly at the battery's maximum load, and the 100A discharge ceiling at 48V covers the pair's combined draw with the controller's current limiting set to the battery's figure, not above it. Energy: at an average draw of 1.5kW, one charge (about 12kWh nominal) is about eight hours of running — one shift at that draw, before the 80% depth-of-discharge planning discipline is applied to it. The break takes up to 100A of opportunity charge, returning up to 100Ah — about two-fifths of the pack — which extends the second shift but does not refill a spent pack; a full recharge is the longer window, about five hours at the standard rate or two and a half at the maximum. Data: the PLC reads SOC over CAN at ≤5% accuracy and schedules the break charge from the battery's own report, which is the integration this model is built for. Enquiry questions: PLC family and protocol documentation, compartment dimensions against the envelope, and the break structure for the opportunity-charge calculation.

The 250Ah system beside the 450Ah system

Read the family's two systems by their integration shape. The 450Ah system is the heavy truck battery: 250A continuous and 600A peak, 12kW maximum load, 350A Anderson connector, CAN plus RS-485, 3000+ cycles, about 280kg. This 250Ah system is the machine battery: 100A maximum discharge, 4kW maximum load, CAN protocol for PLC reading with ≤5% SOC accuracy, a BMS schematic in its documentation, IP53, ≥2000 cycles under stated test conditions, about 115kg. A counterbalance truck spending current and energy by the shift buys the first; a PLC-controlled machine that must report its own state buys the second. The family carries both because industrial 48V duty is two different jobs wearing one voltage.

Inside the case: the 16S5P build, and why it differs from its sibling

This system is built from AL50 3.2V 50Ah cells in a 16S5P arrangement — sixteen in series, five in parallel, eighty cells in total. Set it beside the 450Ah system's 2,160 small cells and the family's two construction philosophies stand side by side: many small cells in a deep parallel build for the heavy system, few large cells in a shallow build for this one. The consequences are practical. Eighty cells is a serviceable count — this model's CAN protocol is provided for PLC reading, and its state-of-charge accuracy is ≤5% — and the shallow build suits the machine-integration role this model is specified for: its equipment context is a pair of 2kW motors with controller and PLC, a 4kW maximum load that matches that context exactly, and a 100A maximum discharge. Neither philosophy is the better one; they are answers to different machines, which is why the family carries both.

The BMS schematic and the ≤5% SOC line: what integration actually buys

Two parts of this model's specification are aimed at the machine builder rather than the battery buyer. The BMS schematic sets out the management system's structure — the document an integrator works from when the battery joins a machine's control system. And the state-of-charge accuracy of ≤5%, alongside the CAN protocol provided for PLC reading, is the figure that decides whether the machine's own controller can trust the battery's reports: a PLC that reads charge state within five percent can schedule work, charging and lockouts against it; one reading a coarse estimate cannot. The IP53 rating completes the integration picture — a system specified to live in a machine compartment, not a battery room. Enquiries from machine builders should arrive with the controller and PLC context stated; the integration conversation starts from those documents, not from the capacity figure.

Commissioning checks for the machine builder

Four checks from the model's own data close the integration job. Envelope: the case dimensions — 170×500×800/850mm — against the machine's compartment, with the dual height figure confirmed for the specific unit at order. Mass: about 115kg against the machine's ballast arithmetic, because a lithium system lighter than the lead-acid unit it replaces changes the machine's stability calculation and the difference is made up deliberately, not discovered. Electrical: the 100A maximum discharge and the 4kW load ceiling against the machine's two 2kW motors and their combined peaks. Data: the CAN provision exercised against the PLC before the machine ships, with the ≤5% SOC figure verified against a known discharge — the integration this model is built for, proven on the bench rather than asserted in the brochure.