Home › Family › 12.8V 200Ah LiFePO4 Power Battery
LiFePO4 power family — model page
12.8V 200Ah LiFePO4 Power Battery
The anchor model of the LiFePO4 power family. This 12.8V 200Ah battery is specified for home storage, storage stations, low-speed EVs, RVs, special vehicles and test, security, survey and medical equipment — a wide brief, backed by a 200A continuous discharge rating and a 2.4kW maximum load.
Key data — 12.8V 200Ah LiFePO4 Battery
| Nominal voltage / capacity | 12.8V / 200Ah |
|---|---|
| Working range | 14.6–10.0V |
| Discharge current | 200A continuous / 450A peak |
| Charge current | 100A standard / 200A max |
| Maximum load | 2.4kW |
| Cycle life | 3000+ cycles |
| Discharge temperature | −20~60 °C |
| Dimensions | 522×238×218/222mm |
| Weight | ≈23kg |
| Options | Bluetooth app, RS-485 |
| Extension | Series / parallel, max 8S |
| Warranty | 12 months |
Electrical ratings
Continuous discharge is 200A with a 450A peak. Standard charge is 100A, maximum 200A, across a 14.6–10.0V working range. Discharge temperature is −20~60°C and cycle life is rated at 3000+ cycles. The warranty period for this model is 12 months.
Options and extension
Bluetooth monitoring through a phone app and RS-485 communication are offered as options. The model supports multi-series and multi-parallel connection, up to 8 in series, for larger banks.
The 12.8V 200Ah specification
Nominal energy is 2.56kWh (12.8V × 200Ah). The discharge figures are the story: 200A continuous — a full 1C — and 450A peak, against a maximum load of 2.4kW. At 12.8V, 200A is about 2.56kW of theoretical throughput, so the 2.4kW load cap is the operative ceiling for sustained work and the 450A peak is reserved for motor starts and inverter surges. Charge is 100A standard (0.5C, a two-hour nominal recharge) and 200A maximum. The working range is 14.6–10.0V: 14.6V is the charge voltage, served by the 14.6V charger class, whose aluminium models run to 25A and 40A and whose 40A unit is the natural pairing for a two-to-three-hour charge at moderate current.
Cycle life is 3000+ cycles — three times the ternary and polymer packs in this catalogue — and the discharge window is −20~60°C. The enclosure is 522×238×218/222mm at about 23kg, roughly 111Wh per kilogram: the density of a lead-acid replacement format, at under half the weight of the lead-acid bank it substitutes for at the same usable capacity.
Series, parallel and monitoring: building a bank
The model supports multi-series and multi-parallel connection up to 8 in series. Two in parallel give a 400Ah 12V bank at 5.12kWh; four in series give a 51.2V-class bank — the same nominal platform as the wall-mounted storage unit, which is the alternative to consider when the installation is fixed rather than vehicular. The options are Bluetooth monitoring through a phone app (state of charge without a separate gauge — the practical choice for RV and marine-style installations) and RS-485 communication for fixed installations reporting to a host system. Choose the option at order time; it is part of the build, not an accessory decision afterwards.
Where the 200Ah model fits
Fields: home storage, storage stations, low-speed EVs, RVs, special vehicles, and test, security, survey and medical equipment. The common thread is a 12V bus with serious current draw — inverter loads, traction motors, winches, pumps. For pure stationary storage duty with a 48V-class inverter, the 51.2V wall unit carries the longer cycle life (6000+ at 90% DOD against 3000+ here) and the parallel architecture; for a 12V vehicle or vessel bus, this model is the catalogue's answer and the 200A continuous rating is why. The warranty period for the model is 12 months.
Designing around the 200Ah figures
The enclosure converts to roughly 20.6 × 9.4 × 8.6 inches and the weight to about 50.7 lb — a two-hand lift, sized to the footprint conventions of the lead-acid group sizes it replaces. Cabling is the design item buyers underestimate at 12V: 200A continuous demands short, heavy-gauge runs and clean terminals, because at 12.8V every milliohm of connection resistance costs real watts and real voltage under load. The 450A peak is a surge figure for inverter starts and motor inrush, not a continuous rating. Fusing belongs at the battery terminal, sized to the cable and the 200A continuous figure, and the Bluetooth option — where fitted — is the practical way to watch state of charge in a vehicle installation without adding a shunt and gauge.
Commissioning checks: a full charge to the 14.6V ceiling and a noted resting voltage, a loaded discharge at the expected continuous draw with terminal temperatures checked after thirty minutes, and — for parallel banks — a per-unit voltage comparison before the bank is closed up, because parallel LiFePO4 units should start life matched. In series strings up to the 8S, the same matching discipline applies and the system charger, not the battery, sets the charge-voltage figure for the string.
Worked example: a service vehicle's 12V system
Take a service vehicle running a 1,500W inverter load (tools, lighting) with a 3,000W surge on motor starts, plus 200W of continuous auxiliaries. Against this battery: the inverter load is 63% of the 2.4kW cap; the surge draws about 234A at nominal voltage, inside the 450A peak; the auxiliaries alone run the 2.56kWh for over twelve hours, and the combined duty — two hours of tool work plus auxiliaries — uses about 3.4kWh of throughput, which is one battery and a parallel twin's worth of planning: two units in parallel (400Ah, 5.12kWh) cover the day with the 8S extension providing the headroom to grow. Charging at the depot on the 14.6V 40A class restores a unit in about five hours. Enquiry questions: Bluetooth or RS-485 option selection for the installation, terminal and cabling specification for 200A service, and parallel-bank configuration confirmation.
Series banks: four units as a 48V-class store
The 4S extension supports the configuration buyers most often build from this battery: four units in series as a 51.2V-nominal, 200Ah bank — 10.24kWh, the energy class of the wall storage family, assembled from portable units. The arithmetic of the bank: charge ceiling 58.4V (four × 14.6V), discharge window 40.0–58.4V, continuous current 200A (unchanged by series), capacity 200Ah (unchanged) — series adds voltage and energy, never current or capacity, and stating that plainly prevents the commonest bank-design error. Balance discipline: units enter the bank at matched state of charge, each unit's own BMS protects its own cells, and the bank is charged as a bank at its own ceiling — never by charging one unit inside the string. Monitoring follows the per-unit options chosen (Bluetooth per unit, RS-485 where fitted). The comparison against the wall family is instructive: the wall unit integrates what the bank assembles, and the bank disassembles into portable 23kg units when the duty moves — the same 10.24kWh, two different ownership models.
Series and parallel extension, in numbers
The model supports multi-series and multi-parallel connection to a maximum of 8 in series. Read what that builds. In parallel, capacity adds: two units are a 12.8V 400Ah bank of 5.12kWh for a vehicle or cabin system that outgrew one battery. In series, voltage adds: two units make a 25.6V-class bank, four a 51.2V-class bank, and eight the ceiling — a 102.4V-class string of 20.48kWh from a single model line, which is how a 12V-native product reaches storage-station voltages without changing supplier. The discipline that travels with extension: units in a bank should be the same model, the same age and the same state of charge at connection, and the bank's charge ceiling is the per-unit 14.6V multiplied by the series count — settled with the inverter or charger before the bank is built, not discovered after.
The communication options, and when each earns its place
Bluetooth and RS-485 are options on this model, and they serve different owners. Bluetooth serves the single-vehicle owner: state of charge, voltage and alarms on a phone, at the battery, with no wiring — the right tool for RV, marine and cabin installations where the battery is reachable and the crew is the owner. RS-485 serves the installation: a wired conversation with an inverter, controller or monitoring system, the right tool where batteries sit in banks, in cabinets or in unattended stations and the state of charge must reach a screen in another room. Neither option changes the electrical ratings on the specification table; both change how the battery is supervised, and supervision is what turns a 3000-cycle rating into 3000 delivered cycles. State which option the installation needs in the enquiry — retrofitting communication to a sealed installation is the expensive way to learn the difference.
The temperature lines, and the duties they describe
The model's discharge window is −20~60°C, which places it honestly in the vehicle-and-cabin world rather than the deep-cold one: the unheated RV in a continental winter, the boat hauled out in a northern yard, the cabin that freezes between visits. It is not the −40°C of the low-temperature family — a buyer whose duty genuinely reaches −40°C belongs on the low-temperature pages, and the enquiry will be routed there if it says so. Within its window, the planning is the usual one: capacity is nameplate, cold reduces what a day returns, and the charge side belongs indoors or in a warmed compartment. The window's top end matters as much in practice — 60°C covers the sun-baked equipment locker that defeats lesser batteries every August.
Applications, walked one by one
The model's applications — RVs, home storage and storage stations among them — divide by supervision style. The RV and vehicle duty is attended: the owner is present, the Bluetooth option earns its place, and the battery's calendar is the touring season, with storage state managed between trips. Home storage is unattended and daily: the RS-485 option and the inverter conversation matter more than the display, and the 3000-cycle rating is spent at the rate of the solar calendar. The storage station — a small commercial or community installation — is the extension duty: units in series and parallel toward the 8-series ceiling, supervised as a bank, serviced as a fleet. One model, three supervision regimes; the enquiry that names its regime gets the options conversation right the first time, which is cheaper than retrofitting it.