24V 60Ah Cold-Storage AGV Battery

A 24V 60Ah battery specified for cold-storage shuttle cars, rack AGVs and unmanned handling vehicles, where the vehicle works in refrigerated space: discharge is rated −40~60°C and charge −20~45°C, with 40A continuous and 120A pulse current, RS-485 communication and a 29.4V 20A matched charger.

Illustration of a low warehouse vehicle carrying a crate

Key data — 24V 60Ah Cold-Storage AGV Battery (−40°C)

Nominal voltage / capacity24V (25.9V) / 60Ah
Cells3.7V 5Ah cells, 7S12P
Discharge40A continuous / 120A pulse
Discharge temperature−40~60°C
Charge temperature−20~45°C
Cycle life≥1000 cycles
CommunicationRS-485, with protocol
Dimensions / weight120×310×330mm / ≈13.5kg
Matched charger29.4V 20A unit

24V 60Ah ratings in full

The battery is built from 3.7V 5Ah cells in a 7S12P arrangement. Discharge is 40A continuous and 120A pulse across a −40~60°C window; charge is accepted from −20~45°C. Cycle life is ≥1000 cycles. The unit measures 120×310×330mm at about 13.5kg, and a 29.4V 20A matched charger comes with the model.

The 24V 60Ah cold-storage specification

Seven series groups of 3.7V cells make the 24V class — the model is also stated at 25.9V nominal — and twelve parallel strings make the 60Ah. Discharge separates into 40A continuous for route work and a 120A pulse, three times the continuous figure, because shuttle duty is acceleration from standstill, repeatedly, all shift. Then the temperatures, which are the model's reason to exist. Discharge runs −40~60°C: a cold store at −25°C sits inside the window with fifteen degrees of margin. Charge runs −20~45°C. The 72V low-temperature model's own charge floor is −10°C. Below −20°C the pack works and does not charge, so the charge point's temperature belongs in the fleet plan beside the route map. Communication is RS-485 with the protocol supplied, so the fleet system reads the pack's state the same way it reads the 48V model's. Cycle life is ≥1000 cycles, quoted for a duty that can run several rotations a day.

The matched 29.4V 20A charger

The charger supplied with this model outputs 29.4V±1% at 20A±10% — 588W, efficiency of 85% or better, in a 220×120×70mm unit. Read the pairing correctly: 29.4V is the charger's output ceiling for this 24V-class battery, and 20A is the charger's output current. At 20A a full 60Ah recharge is roughly a three-hour turnaround, which is the number the spare-pack pool is sized against. The wider charger line's 24V class (29.4V outputs in aluminium and plastic shells) is grouped on the 24V charger page; the match for this battery is the unit above.

Running AGVs in refrigerated space

Cold-storage automation fails on batteries more than on mechanics, because standard lithium packs lose their discharge rating as temperature falls — a pack adequate at 20°C may deliver a fraction of its current at −25°C, and the vehicle faults under load. The selection arithmetic is therefore done at the working temperature: this model's discharge window runs to −40°C, so the store's working temperature can be checked against a stated floor instead of an adjective. Buyers speccing a cold-store fleet should confirm three numbers per vehicle: rack aisle temperature against the −40°C discharge floor, charge-point temperature against the −20°C charge floor, and per-shift energy against the 60Ah (about 1.44kWh nominal). Condensation is the cold-store specific hazard: a vehicle that works at −25°C and charges in a warmer dock crosses the dew point twice per cycle, so connectors and case seams want inspection intervals shorter than a temperate fleet's, and charging should start after the pack has stood long enough for surface moisture to clear. Commissioning belongs in the cold room, not the workshop: run the real route at working temperature, log energy per shift and the voltage behaviour under acceleration peaks, and set the fleet's charge rotation from measured figures.

Worked example: a cold-store shuttle on three rotations

Take a cold store at −25°C running shuttle vehicles in three rotations across 24 hours. Per rotation the vehicle draws about 1.1kWh measured against its route; this pack stores about 1.44kWh nominal, so one pack covers one rotation with reserve — the fleet pattern is three packs per vehicle position: one working, one charging (about three hours at the matched 29.4V 20A unit), one ready. The pattern rests on the figures above: the discharge floor of −40°C against the store's −25°C, the charge floor of −20°C checked against the charge point, the 120A pulse for shuttle acceleration, and ≥1000 cycles against a multi-rotation day, budgeted at purchase. Enquiry questions: dock charging layout, condensation management practice for the warm-cold cycle, and rotation-pool sizing for the vehicle count.

The 24V cold-storage model beside the 48V AGV battery

The family's two anchor batteries divide by temperature and cycle ambition. The 48V 40Ah model: LiFePO4 cells, 40A continuous with the same 120A pulse, RS-485 with host software, 3000+ cycles, a 54.0V 18A matched charger. This 24V model: half the voltage, half again the capacity, a −40°C discharge floor with a −20°C charge floor, RS-485, and ≥1000 cycles. A fleet that works above freezing and cycles for years buys the 48V model's cycle life; a fleet that works in a freezer buys this model's temperature windows and budgets this model's ≥1000-cycle rating into the rotation pool. Size each fleet on its own model's duty — the 48V fleet on its 3000+ cycles, the freezer fleet on its −40°C discharge floor.

Inside the case: the 7S12P build

The battery is built from 3.7V 5Ah cells in a 7S12P arrangement — seven in series for the 24V class (the model is also stated at 25.9V nominal), twelve in parallel for the 60Ah, 84 cells in total. The build explains the current table: 40A continuous spreads across twelve parallel strings at about 3.3A per string, while the 120A pulse draws about 10A per string — the ratio a start-stop shuttle duty produces, sized so the pulse is a working event rather than an emergency one. It also explains the envelope: 120×310×330mm is a flat, low case, shaped for a shuttle deck rather than a battery room, and at about 13.5kg it is a two-hand carry for the technician who swaps it. When a cold-store fleet standardises, this is the unit of standardisation: one case, one connector conversation, one spare on the shelf.

The dock is the charge point: planning the rotation

Cold-store logistics charge at the dock because the dock is where the temperature is: the battery works at discharge temperatures down to −40°C and charges from −20°C, so a charging corner at the cold-store entrance sits inside both windows while the freezer aisle sits inside only one. The matched charger — 29.4V, 20A, 588W — turns a flat 60Ah battery around in roughly three hours; a shuttle that works a four-hour rotation therefore runs a two-pack pool per vehicle with margin, and a fleet of six shuttles is a twelve-pack pool plus two spares and seven charge points, or fewer points on a staggered schedule. The RS-485 line is what makes the pool manageable: charge state reported per pack, so the rotation is dispatched on data. Send the vehicle count, the rotation length and the dock temperature with the enquiry and the pool arithmetic comes back done.

Communication and the protocol document

The battery carries RS-485 communication with protocol, and in a cold-store fleet that line carries more weight than its six words suggest. The fleet system that dispatches shuttles can poll each pack's state before assigning a rotation, hold a tired pack at the dock instead of discovering it mid-aisle at −28°C, and log the charge history the replacement budget runs on. Integration starts with the protocol document, requested with the first enquiry alongside the vehicle count and rotation pattern; the questions it answers — polling, addressing, the data the pack reports — are the difference between a fleet that is managed and a fleet that is merely counted. The battery's electrical table does not change with the integration tier, but the fleet's behaviour does.

Related pages