Home › Family › 24V Lithium Battery Chargers
Charger family — 24V class
24V Lithium Battery Chargers
Eight models at the 29.4V ceiling that 24V lithium packs charge toward — five aluminium currents from 2A to 20A and three plastic-shell units — plus a ninth model at its own 33.6V ceiling, the 10A aluminium unit for the 28.8V class. The cold-storage AGV battery's matched charger is its own 29.4V 20A unit, supplied with the battery — a different model from the standalone 29.4V 20A aluminium unit in this class.
Key data — 24V Lithium Battery Chargers
| Shell | Aluminium (six models); plastic (three models) |
|---|---|
| Outputs | 29.4V (2A–20A); 33.6V (10A) |
| Series fields (aluminium) | 220Vac input in selected models; ≥85% efficiency; red/green LED; 1.5m input cord, 1.0m output cord |
The 24V class models
| 29.4V 2A — aluminium | 29.4V±0.2; 2A±5%; 58.8W; 120×90×50mm; 0.7kg |
|---|---|
| 29.4V 5A — aluminium | 29.4V±0.2; 5A±5%; 147W; 170×90×50mm; 1kg |
| 29.4V 10A — aluminium | 29.4V±0.2; 10A±10%; 294W; 170×90×63mm; 1.2kg |
| 29.4V 15A — aluminium | 29.4V±0.2; 15A±10%; 441W; 220×120×70mm; 2.5kg |
| 29.4V 20A — aluminium | 29.4V±0.2; 20A±10%; 588W; 230×135×70mm; 3.0kg |
| 33.6V 10A — aluminium | 33.6V±0.2; 10A±10%; 336W; 170×90×63mm; 1.2kg (the 28.8V-class model) |
| 29.4V 2A — plastic | 29.4V±0.2; 2A±10%; 58.8W; 109×49×30mm; 190g |
| 29.4V 3A — plastic | 29.4V±0.2; 3A±10%; 88.2W; 142×61×32mm; 280g |
| 29.4V 4A — plastic | 29.4V±0.2; 4A±10%; 117.6W; 172×73×35mm; 470g |
Reading the 24V class table
One ceiling, five aluminium currents: the class is a turnaround ladder. A 24V 60Ah pack on the 5A unit is an overnight charge of about twelve hours; on the 10A, about six; on the 20A, about three — and which rung a fleet buys is set by the rotation pattern, not by the battery alone. The battery's own charge limit governs which rungs are permissible, and where a battery's data states no charge-current limit, the charger is not evidence of one: the pairing is confirmed at enquiry. That distinction matters in this class more than any other, because the cold-storage model's matched charger is also a 29.4V 20A unit — its own model, supplied with the battery with its own tolerances (29.4V±1%, 20A±10%) — while the standalone aluminium 29.4V 20A in the table above is a catalogue model with a different suffix and a ±0.2V tolerance. Same ceiling, same current, different units; the enquiry should say which one it means. The 33.6V 10A row serves the 28.8V class and shares the shelf with this class; its ceiling does not substitute for 29.4V on a 24V pack. Plastic-shell units (2A, 3A, 4A) cover point-of-use charging for smaller 24V packs.
Specifying a 24V charger enquiry
State the pack's capacity, its charge limit where it has one, and the turnaround the duty needs. Cold-store fleets should also state the charge-point temperature: the cold-storage battery's charge floor is −20°C, a battery fact that decides where in the building the chargers live. Efficiency across the aluminium series is 85% or better, with red/green indication; case sizes and weights are per model, not shared across the series.
Which batteries these ceilings serve
The 29.4V models serve 7S lithium packs — the class of the cold-storage AGV battery, whose 7S12P build tops its working range at 29.4V. That battery's matched charger is a 29.4V 20A unit supplied with the battery; the standalone 29.4V models on this page — 2A, 5A, 10A, 15A and 20A in aluminium, 2A, 3A and 4A in plastic — are separate products selected against a battery's ceiling and charge limit at enquiry, and the similarity of figures does not make them the matched unit. The 33.6V aluminium model serves the 28.8V-class packs, a distinct ceiling that should never be substituted for 29.4V on a 7S pack. Ceiling first, battery second, current third — and in this class, a fourth question: matched or standalone, because the catalogue contains both and they are not the same line on the order.
The current ladder and cold-store duty
Eight models share the 29.4V ceiling — 2A, 5A, 10A, 15A and 20A in aluminium, 2A, 3A and 4A in plastic — and the ninth model stands apart at 33.6V, the 10A aluminium unit for the 28.8V class. The spread of currents exists because 24V-class duty spans devices to vehicles. The plastic 2A–4A rungs are bench and service charging. The aluminium 5A and 10A rungs are the small-fleet overnight pattern. The 15A and 20A rungs are turnaround charging — the cold-store rotation, where a 60Ah shuttle battery on a 20A-class unit refills in about three hours and the fleet's spare pool is sized by that figure. The depot arithmetic uses the rated wattages: the 20A aluminium model at 588W nameplate, divided by the series' 85%-or-better efficiency, is under 700W from the wall per charge point, so a six-point cold-store depot is a 4.2kW circuit conversation. The aluminium rungs share the aluminium series' working furniture — IEC socket, two-LED indication, 1.5 m power cord, 1.0 m output cord — so a depot running the aluminium line can mix those rungs on one shelf standard.
The 29.4V 2A aluminium rung
The 29.4V 2A aluminium unit is the aluminium series' lowest-output rung on this page: 29.4V ceiling, 2A, 58.8W rated output. Buyers cross-shopping quotations from several suppliers should compare those three figures — ceiling, current and rated wattage — against the battery each charger will serve; a quotation that gives only a model name gives nothing to check the pairing against.
Matched or standalone: the order-line distinction
One distinction should appear verbatim on every 24V-class order: whether the unit being bought is the matched charger supplied with a specific battery or a standalone model from this page. The figures can coincide — the cold-storage battery's matched unit and this page's 20A aluminium model are both 29.4V-class units — while the products remain different lines, with different model data. Orders that blur the distinction create receiving disputes that nobody wins; orders that state it get the unit they meant, with the right documents in the box.