English

Home › Family › 60V 25Ah Low-Temperature Lithium Battery Pack

Low-temperature family — model page

60V 25Ah Low-Temperature Lithium Battery Pack

A 60V 25Ah pack in the high/low-temperature resistant build of the family, using 3.7V 5000mAh cells in a 5P16S arrangement. It discharges across the same −40~60°C window as the 72V 50Ah pack, in an 8.5kg envelope for equipment that does not need 50Ah.

Illustration of a battery pack with snowflakes and a thermometer

Key data — 60V 25Ah Low Temperature Lithium Battery

Nominal voltage / capacity60V / 25Ah
Working range67.2–40.0V
Cell combination3.7V 5000mAh, 5P16S
Discharge current20A continuous / 60A pulse
Maximum load≤1200W
Cycle life≥1000 cycles
Discharge temperature−40~60 °C
Dimensions75×200×365mm
Weight≈8.5kg

60V 25Ah ratings in full

Working range is 67.2–40.0V. Continuous discharge is 20A with a 60A pulse, for loads up to 1200W. Cycle life is rated at ≥1000 cycles, and the pack measures 75×200×365mm.

The 60V 25Ah specification

The arrangement is 5P16S: five parallel strings of sixteen series cells, each cell 3.7V 5000mAh. Sixteen times 4.2V gives the 67.2V top of the working range; the range runs down to 40.0V. Five parallel 5Ah cells give 25Ah, and nominal energy is about 1.5kWh in an 8.5kg pack. The 72V 50Ah pack's own figures are 3.6kWh in a 22kg pack.

Continuous discharge is 20A (0.8C), pulse 60A, maximum load 1200W. At nominal voltage, the 20A continuous current and the 1200W load cap are the same boundary — 60V × 20A is exactly 1200W — so size sustained loads against 1200W and transient loads against the 60A pulse. Cycle life is ≥1000 cycles, the same rating as the 72V 50Ah pack.

60V or 72V: choosing inside the family

The 60V 25Ah pack and the 72V 50Ah pack divide by weight and load. The 60V 25Ah pack suits equipment one person carries or mounts — instruments, light vehicles, field devices — where 1.5kWh and 1200W cover the duty and 8.5kg is the difference between portable and fixed. The 72V 50Ah pack carries 3.6kWh of nominal energy and a 2500W load cap at 22kg. Both share the −40~60°C discharge window and the family's high/low-temperature resistant build, so the choice is never about cold rating; it is about energy, watts and kilograms. Buyers between the two should also note the intermediate classes — 60V up to 50Ah and 72V from 20Ah — whose figures are confirmed on enquiry.

Charging and handling the 60V pack

Charge voltage class is 67.2V, served in the charger line by the aluminium-shell 67.2V 10A model (672W). The pack's own charge limits are confirmed on enquiry; the class pairing itself is direct — a 60V ternary pack charges at 67.2V, and using a lower-voltage charger class would leave the pack chronically undercharged. At 75×200×365mm the envelope is a flat slab, suited to under-seat, bulkhead and instrument-case mounting; for carried equipment, the flat form and the 8.5kg weight are the practical pick over the 72V 50Ah pack.

Designing around the 60V 25Ah figures

The envelope converts to roughly 3.0 × 7.9 × 14.4 inches and the weight to about 18.7 lb — one hand under a handle, the classic instrument case format. Continuous discharge is rated at 20A — 0.8C against the 25Ah capacity — with a 60A pulse rating above it, and cycle life is rated at ≥1000 cycles. Size the working load to the continuous figure: the pulse rating is a ceiling for start surges, not a running rate. The flat-slab form factor wants a tray, sleeve or bulkhead mount with the large faces supported; point pressure and edge impacts are the mechanical enemies of any flat pack, this one included.

In service, the checks are the family checks: charge inside the charge window (the charger class pairing is 67.2V; the model's own charge limits are confirmed on enquiry) — and log the first deep-cold discharge against its load. Buyers speccing carried equipment should prototype the mount with the real 8.5kg early — carried weight has a way of growing between datasheet and deployment, and this pack's entire purpose is that it does not have to.

Worked example: a carried instrument station

Take a portable instrument station drawing 300W average with 900W peaks, carried to site by one technician. Against this pack: 300W is a quarter of the 1200W cap; peaks draw about 15A at nominal voltage, inside the 20A continuous rating without touching the 60A pulse. Energy 1.5kWh against 300W is five hours of station time — a working session, with the 8.5kg pack as the heaviest single item in the kit and still a one-hand carry. The same station on the 72V 50Ah pack would run twelve hours but add 13.5kg: the worked example is the family's selection logic in miniature. Enquiry questions: the model's own charge limits and matched charger confirmation (the 67.2V class pairing), carry-case or tray mounting options, and parallel or spare-pack practice for multi-session days.

Charging this model: the 67.2V class

The 60V pack's working range tops out at 67.2V, and the charger line's 60V/72V class includes the matching rung: a 67.2V 10A aluminium model at 672W. That 10A is the charger's rating, not this pack's. For this model, charge current is an enquiry item: no charge time for the pack can be read off the charger line — the pairing, and the rate the pack accepts, are confirmed at enquiry against the model. The aluminium series' shared fields apply to that model as they do across the line: efficiency of 85% or better at rated load, red/green two-LED indication, IEC input socket, 1.5 m power cord and 1.0 m output cord. Two cautions ride along. First, charging temperature for this model is set at enquiry — do not borrow the 72V 50Ah model's −10°C charge floor, which is that model's figure. Second, the 84.0V model on the same class page belongs to the 72V packs; the two ceilings are not interchangeable, and a depot that runs both classes should label its charge points by ceiling, not by vehicle.

60V or 72V? Reading the two vehicle packs against each other

The family's two vehicle packs divide by installation, not by merit. Energy: 1.5kWh against 3.6kWh. Continuous discharge: 20A against 40A; pulse: 60A against 120A; maximum load: 1200W against 2500W. Envelope: 75×200×365mm and about 8.5kg — a one-person carry that bolts into an existing battery tray — against 150×215×425mm and about 22kg, a two-person lift that is planned like equipment. Cycle rating: the same ≥1000 on both. The 60V model is the answer where the vehicle or instrument was designed around a lighter pack and the duty is measured in hundreds of watts; the 72V model is the answer where the load profile runs into kilowatts and the working day is long. Enquiries that state the average draw, the peak draw and the coldest working temperature get a one-line recommendation back; enquiries that state only a voltage get a question.

The cell build: 5P16S

The pack is built in a 5P16S arrangement — five parallel strings of sixteen series cells — and the arrangement is the shortest accurate description of its character. Sixteen in series makes the 60V class and its 67.2–40.0V working range; five in parallel makes the 25Ah and divides the current duty five ways, so the 20A continuous rating asks about 4A of each string and the 60A pulse about 12A. Builders comparing packs should ask for the arrangement with the same directness as the capacity: two 25Ah packs with different builds are different products wearing the same label, and the cycle figures will eventually say which was which.

Related pages