A module format rather than a finished pack: a 3.7V parallel cell module rated at 18Ah and 66.6Wh, with a 15A maximum charge, ≤36A continuous discharge and a ≤100A pulse, for buyers assembling their own packs for electric vehicles, forklifts, robots, AGV and special equipment.
Key data — 3.7V Parallel Cell Module
| Nominal voltage / capacity | 3.7V / 18Ah (66.6Wh) |
|---|---|
| Working range | 4.2–3.0V |
| Maximum charge current | 15A |
| Discharge | ≤36A continuous / ≤100A pulse |
| Maximum load | ≤120W |
| Cycle life | ≥500 cycles |
| Internal resistance | ≤3–6mΩ |
| Dimensions / weight | 42×72×100mm / ≈440g |
Module ratings in full
The module's working range is 4.2–3.0V. Maximum charge current is 15A; continuous discharge is ≤36A with a ≤100A pulse, against a maximum load of ≤120W. Cycle life is ≥500 cycles, internal resistance is ≤3–6mΩ, and the unit measures 42×72×100mm at about 440g.
The module specification
Read the figures as a set. The energy is 66.6Wh — the module is a capacity block, and pack energy is built by combining blocks. The load ceiling is the discipline line: ≤120W maximum load sits well under what the raw current figures would suggest (36A at 3.7V is about 133W), so the load cap, not the current cap, is the operative limit for sustained work, with the ≤100A pulse reserved for transients. Charge at up to 15A is fast for a module of this size — a full charge in a little over an hour at the ceiling — and the ≥500-cycle rating is the figure pack builders should carry into their own product's life calculation, at the module's stated conditions. The resistance line (≤3–6mΩ) is the quiet figure behind the pulse rating: low resistance is what keeps voltage sag manageable when a parallel block is hit with a pulse load.
Where the module fits
The module's application list: electric vehicles, forklifts, robots, AGV and special equipment. Those duties make the module a building block for vehicle and machine builders whose pack geometry is their own, in the same duties the catalogue's finished industrial batteries serve. Against the finished packs in this family (the 48V 52Ah pack, the 18650 packs with built-in BMS), the module trades completeness for geometry: protection, housing, interconnect and certification of the finished pack sit with the buyer, and that trade should be made deliberately, with the engineering priced in — the BMS, the enclosure, the test time and the certification file, not just the module invoice.
Specifying a module enquiry
State the finished pack's target voltage and capacity (which set the series and parallel counts), the continuous and pulse draw the interconnect must carry against the module's ≤36A / ≤100A lines and ≤120W load cap, the charge current intended against the 15A maximum, and the matching tolerance the build requires across the order. Buyers whose end product carries its own certification should start that conversation at the module order, because the module's data — the ≥500 cycles, the 4.2–3.0V window, the charge and load limits — goes into the pack-level file.
The parallel ladder, in numbers
A module is a building block, and the builder's arithmetic runs on the ladder. One module: 3.7V, 18Ah, 66.6Wh, maximum charge 15A, continuous discharge ≤36A, pulse ≤100A. Two in parallel: 36Ah and 133.2Wh — and the current ceilings stay the single module's own, stated per module — 15A maximum charge, ≤36A continuous discharge, ≤100A pulse. Four: 72Ah, 266.4Wh. Eight: 144Ah, 532.8Wh — a traction-scale bank assembled from identical 42×72×100mm units of about 440g each, serviceable one module at a time. The discipline of parallel assembly is uniformity: modules combined should be the same production batch, at the same state of charge, connected through protection appropriate to the combined current — the combined pulse ceiling of an eight-module bank is a serious current, and the wiring, fusing and switching are sized to it, not to the single module's figures. State the target capacity and the load profile in the enquiry and the combination is specified as a set, with its combined ratings stated as a set.
What ≤120W of load means in practice
The module's maximum load is ≤120W, and that line — not the current figures — is the honest sizing gate for small equipment. A 120W ceiling covers the catalogue's named duties comfortably: instrument and monitoring loads measured in watts, robot subsystems and AGV auxiliary circuits, special-equipment electronics. The line is drawn in watts, not in load types: any load above 120W — traction, heating or otherwise — is outside the module's rating, which is information, not apology. The ≥500-cycle rating belongs in the same planning pass: it is a count to budget against the duty's cycling rate — state the expected cycles per week in the enquiry and the replacement rhythm is planned against the count, not against a calendar. And the ≤3–6mΩ internal resistance is the figure behind the pulse rating: across a 100A pulse, resistance at that level sags the module's voltage by a fraction of a volt, which is why the pulse can be nearly three times the continuous rating without the output collapsing.
Applications, walked one by one
The application list — electric vehicles, forklifts, robots, AGVs and special equipment — reads at module scale, not vehicle scale: this unit serves inside those machines, not instead of their traction packs. In an AGV it is the auxiliary and control supply, or the traction supply of the smallest platforms. In a forklift it is instrumentation and control power. In robots and special equipment it is the primary pack where the whole machine's budget is a hundred watts. The selection question is therefore not "which vehicle" but "which circuit": name the load, its continuous and peak draw, and the space it lives in, and the module count follows from the ladder above. Enquiries that arrive in that form are answered with a specified combination; enquiries that arrive as a vehicle model number get the circuit questions back first.
Handling, storage and the unglamorous lines
Modules are bought by builders, and builders plan the shelf as well as the circuit: identical modules, stored part-charged in a cool dry store, rotated so the bank is built from units of one age. The 440g unit mass and the 42×72×100mm envelope make the storage arithmetic easy — a hundred modules are 44kg and a single shelf — and the combination discipline starts there: units drawn from one batch, at one state of charge, assembled in one session — and that discipline is what decides whether the finished bank performs to the module ratings. The enquiry that mentions its build quantity gets the batch conversation included in the quotation, which is where it belongs.