Home › Family › 48V 40Ah LiFePO4 AGV Battery
AGV family — model page
48V 40Ah LiFePO4 AGV Battery
A 48V 40Ah lithium iron phosphate battery built from 26650 3.2V 3300mAh cells in a 15S13P arrangement, for AGV, RGV and warehouse logistics equipment. It communicates over RS-485 with host-computer software and protocol, and comes with a matched 54.0V 18A charger.
Key data — 48V 40Ah AGV Battery
| Nominal voltage / capacity | 48V / 40Ah |
|---|---|
| Working range | 54.0–37.5V |
| Cells | 26650 3.2V 3300mAh LiFePO4, 15S13P |
| Discharge | 40A continuous / 120A pulse |
| Charge | 20A suggested / 40A maximum |
| Maximum output | 1.8kW |
| Cycle life | 3000+ cycles |
| Communication | RS-485, host-computer software and protocol |
| Internal resistance | ≤80mΩ |
| Case / size / weight | Black sheet-metal case, baked paint / 165×265×425mm / ≈25kg |
| Warranty | 12 months |
| Matched charger | 54.0V 18A unit |
48V 40Ah ratings in full
Continuous discharge is 40A with a 120A pulse; maximum output is 1.8kW. Charge is 20A suggested and 40A maximum across a 54.0–37.5V working range. Cycle life is 3000+ cycles, and the unit measures 165×265×425mm at about 25kg in a black sheet-metal case with a baked-paint finish.
The 48V 40Ah AGV specification
Cells are 26650-format 3.2V 3300mAh LiFePO4 in 15S13P: fifteen series groups give the 48V class (the working range tops out at 54.0V, the charge ceiling the matched charger is built to), and thirteen parallel cells give the 40Ah rating. Discharge separates into the two figures a fleet actually plans around: 40A continuous for route work, and a 120A pulse for acceleration and incline starts — three times the continuous figure, which is the headroom that keeps a loaded vehicle from tripping protection at every ramp. Charge is 20A suggested for routine fleet charging and 40A maximum where turnaround demands it. Internal resistance is ≤80mΩ. Cycle life is 3000+ cycles: at one cycle per working day that is a decade-class horizon; at two cycles a day, five years. Communication is RS-485 with host-computer software and the protocol supplied: the vehicle or fleet system reads pack state directly, which is what separates an AGV battery from a traction battery with a comms port drawn on the brochure.
The matched 54.0V 18A charger
The model comes with a matched charger: 54.0V±0.5V output at 18A±5%, 972W, efficiency of 85% or better, AC 200–240V input, 304×175×90mm and 4.5kg, giving a charge time of about three hours. The pairing logic is in the numbers: 54.0V is exactly the top of the battery's working range, and 18A sits just under the 20A suggested charge rate, so the matched charger runs the pack at its routine rate without exceeding it. Fleets running two shifts should size charger count from the three-hour figure and the shift pattern, not from the battery count alone. Note the distinction: this matched unit belongs to this AGV battery; the wider charger line's 48V class (54.6V and 57.6V outputs) serves other 48V packs, and charge voltage is not a figure to approximate.
Where the 48V 40Ah battery fits
Application fields for the model: AGV, RGV and MGV vehicles, robots, low-speed electric vehicles, mobility scooters, communications and medical equipment, solar street lights, home storage and storage stations. The specification pattern — flat sheet-metal case, a 120A pulse over a 40A continuous base, RS-485 host reporting, 3000+ cycles — is a fleet pattern: vehicles that return to a charge point, report their state, and cycle daily for years. Against the family's 24V 60Ah cold-storage model, this battery trades the −40°C discharge window for double the voltage and three times the cycle rating. Selection is duty-first: temperature, then cycles, then capacity.
Integrating the 48V 40Ah pack into a vehicle
The case converts to roughly 6.5 × 10.4 × 16.7 inches and about 55 lb. Sheet metal, unlike shrink film, is a mounting surface: bolt it down, and design the vehicle's centre of gravity with the 25kg low in the chassis, where AGV designers want mass anyway. The drivetrain check runs off the pair — controllers sized for 40A continuous route draw with the 120A pulse absorbing starts — because the protection system will enforce the pack's limits whether the controller expects it or not. RS-485 integration is the other design task: the host software reads pack state over the bus, so the vehicle's charge scheduling, fault handling and fleet dashboard all key off this battery's own reporting — allocate the software work in the project plan, not as an afterthought. Commissioning a fleet unit: full charge on the matched charger, a full-route discharge under the vehicle's real duty (not a bench load), a comms log review for dropouts, and a recorded baseline of route energy per shift. That baseline is the number the whole fleet's charger count and spare-pack pool are sized from, and it can only be measured, not quoted.
Worked example: a two-shift warehouse fleet
Take a warehouse AGV drawing an average 400W across a route, two eight-hour shifts daily. Energy per shift is 3.2kWh; this pack stores about 1.92kWh nominal — one pack per shift is not enough, which is the normal AGV answer and not a defect: the fleet pattern is pack swap or opportunity charge. With the 54.0V 18A matched charger, a one-hour mid-shift charge returns roughly 0.9kWh, so the workable patterns are: two packs per vehicle rotating through chargers, or one pack per vehicle with two one-hour opportunity charges per shift, sized from the vehicle's real idle windows. Cycle arithmetic: at two cycles daily, the 3000+ rating is a four-year-plus horizon per pack. Enquiry questions: RS-485 protocol documentation for the host integration, charger-count sizing for the fleet, and spare-pool configuration.
Fleet maintenance practice for this pack
Maintenance on a communicating fleet pack is a data routine, not a workshop routine. Monthly: pull the RS-485 logs and read three numbers per vehicle — deepest discharge of the month, highest charge temperature, and cycle count increment. The first catches route creep (a vehicle suddenly discharging deeper has a route problem, not a battery problem); the second catches ventilation and charger faults; the third keeps the 3000-cycle horizon honest against the fleet's replacement budget. Quarterly: a reference discharge on one pack per age cohort, compared against its commissioning baseline — the fleet learns its real ageing rate from its own data instead of from brochure figures. Physically: the steel case wants an annual inspection for route damage, and the 165×265×425mm envelope is the handling unit for tray and spare-rack design. None of this requires the pack to leave service except the quarterly reference test — the maintenance case for buying the communicating tier, stated as a calendar. The warranty period for the model is 12 months.
Inside the case: the 15S13P build
The pack is built from 26650-format 3.2V 3300mAh cells in a 15S13P arrangement — fifteen in series for the 48V class (the model's working range runs 54.0–37.5V), thirteen in parallel for the 40Ah, 195 cells in total. The arrangement explains two other lines on the table. The 40A continuous rating spreads across thirteen parallel strings, so each string carries about 3A — a gentle per-cell duty that is part of how the model reaches its 3000-cycle rating. And the ≤80mΩ internal resistance is the pack-level figure behind the 120A pulse: resistance, multiplied by pulse current, is the voltage sag the vehicle's controller sees at the moment of acceleration, which is why the figure is rated at all. Buyers comparing AGV packs across suppliers should ask for the cell format and arrangement with the same seriousness as the headline capacity — two 40Ah packs built differently age differently.
The host-computer conversation
The model carries RS-485 communication with host-computer software and protocol, which moves it out of the dumb-battery class: a fleet host can poll state of charge, voltage and status across vehicles from one screen, schedule opportunity charging against real charge data rather than timers, and log the discharge history that warranty and replacement planning both run on. Integration questions belong in the first enquiry, not the fifth: the protocol document, the polling model the host expects, and whether the fleet software reads the pack directly or through the vehicle's controller. None of this changes the electrical table — 40A continuous, 120A pulse, 1.8kW maximum output — but it decides whether a twenty-vehicle fleet is managed as a fleet or as twenty separate surprises.
The matched charger, in full
The battery's matched charger is a 54.0V 18A unit, and its data repays reading as a pair with the battery's own: output 54.0V ±0.5V at 18A ±5%, 972W, efficiency ≥85%, input AC200–240V, dimensions 304×175×90mm, mass 4.5kg, and a full charge in about three hours. Set the pair side by side and the design intent shows: the charger's 54.0V ceiling is the battery's range top (54.0V), its 18A sits just under the battery's 20A suggested charge, and its three-hour turnaround is the fleet's rotation unit. The unit belongs to this battery — it is not a forklift charger, not a generic 54V-class unit, and not interchangeable with the standalone models on the charger pages that happen to share figures. A fleet that standardises on this battery standardises on this charger with it, and orders the pair as a pair.
Reading the warranty and the case
Two quieter lines complete the model's picture. The warranty is 12 months — the industrial family's standard term in this catalogue, against the storage family's 36 — and a fleet buyer should read it as part of the duty statement: this is a working battery in a working vehicle, warranted as one. The case is black sheet metal with a baked-paint finish, which is the repairable, dent-tolerant, fleet-workshop choice — a case that can be opened, serviced and repainted across a 3000-cycle life rather than a sealed skin that cannot. Neither line appears in a headline, and both appear in the total cost of a fleet across five years. Enquiries that ask about service procedure and spare cases alongside price are the ones quoted by people who have run fleets before.