Key data — 48V Lithium Battery Chargers
| Shell | Aluminium (four models); one plastic-shell model |
|---|---|
| Outputs | 54.6V (2A, 4A) and 57.6V (10A, 15A) |
| Series fields (aluminium) | 220Vac input in selected models; ≥85% efficiency; red/green LED; 1.5m input cord, 1.0m output cord |
The 48V class models
| 54.6V 2A — aluminium | 54.6V±0.2 output; 2A±5%; 109W maximum power; 135×90×50mm; 0.8kg |
|---|---|
| 54.6V 4A — aluminium | 54.6V±0.2 output; 4A±5%; 147W maximum power; 170×90×50mm; 1kg |
| 57.6V 10A — aluminium | 57.6V±0.2 output; 10A±10%; 576W maximum power; 220×120×70mm; 2.5kg |
| 57.6V 15A — aluminium | 57.6V±0.2 output; 15A±10%; 864W maximum power; 230×135×70mm; 3.0kg |
| 54.6V 2A — plastic | 54.6V±0.2 output; 2A±10%; 109.2W maximum power; 172×73×35mm; 470g |
Case sizes are per model: there is no single shared case dimension across the aluminium series.
Reading the 48V class table
The class divides first by ceiling. A 48V ternary pack charges toward 54.6V; a 48V-class LiFePO4 system charges toward 57.6V; the two ceilings never substitute for each other, and the three-volt difference is exactly the borrowed-charger fault that leaves a fleet undercharged for a season. Within a ceiling, current is the turnaround decision: at 2A a 20Ah ternary pack is an overnight charge; at 4A the same pack turns around in about five hours; the 57.6V rows at 10A and 15A are bench and fleet rates for LiFePO4 systems whose own charge limits admit them — the battery's maximum charge current governs, always. The 15A / 864W model is the highest-power charger in the line. Tolerances run per model (±5% on the 54.6V aluminium pair, ±10% on the 57.6V pair and the plastic unit), and efficiency across the aluminium series is 85% or better at rated load, with red/green charge indication and an IEC-standard input socket.
Specifying a 48V charger enquiry
State the pack's chemistry and charge ceiling first (54.6V or 57.6V), its capacity, and its maximum charge current; the class choice and current follow from those three facts. Fleets should also state the turnaround the shift pattern needs: the difference between the 2A overnight unit and the 15A fleet unit is a building decision (circuits, heat, charger count) as much as a purchase one. Note for AGV buyers: the 48V 40Ah AGV battery's matched charger is its own 54.0V 18A unit, supplied with the battery; the models in this class are the standalone catalogue line, a separate set.
Which batteries these ceilings serve
A charger class is defined by the batteries across the catalogue whose ceilings it matches. The 54.6V models serve the 48V-class ternary packs — the 48V 52Ah pack's working range tops at exactly 54.6V, so only the 54.6V rungs on this page serve it; the 57.6V rungs sit above its ceiling. Its ≤20A charge limit is met by every 54.6V rung on the page. The 57.6V models serve 16S LiFePO4: the 51.2V 100Ah wall unit's working range tops at 57.6V. That unit's own standard charge is 50A; the 10A and 15A rungs are its slow answers — overnight and service charging of the single wall unit, below its standard rate, on depot time rather than battery time. The plastic 54.6V 2A model serves the bench: service departments, low-rate maintenance charging, and packs whose own limits are small. Read the class this way — ceiling first, battery second, current third — and the five models sort themselves; read it current-first and every depot ends up with a fast charger on a battery that cannot take it.
Rated wattage governs
The 54.6V 4A aluminium model is rated at 147W, and the 42V-class 5A model on the 36V charger page likewise — figures below the naive product of volts and amps, because a charger's wattage is its rated output under its own test conditions, not an arithmetic identity. Buyers sizing depot circuits should plan from the rated wattage and the ≥85% efficiency: a 147W charger draws under 175W from the wall at full output, and ten of them are a 1.75kW circuit conversation, not a 2.2kW one. The rated figure is the planning figure.
Input ranges and depot wiring
The aluminium series carries 220Vac input on selected models across a 200–240Vac range at 50–60Hz, with an IEC input socket and a 1.5 m power cord — the depot pattern: chargers racked or shelved on a shared circuit, swapped without tools, indicated by the red/green two-LED pair every model in the series carries. The wiring arithmetic uses the rated wattages and the 85%-or-better efficiency: sum the nameplates, divide by 0.85, and the circuit is sized with the answer plus the electrician's margin. The output side is a 1.0 m cord on every model, which fixes the depot geometry — charge points within a metre of the batteries they serve. Fleets standardising on this class should standardise the shelf, the circuit and the labelling with the chargers; across the aluminium series the IEC input socket, the 1.5 m power cord, the 1.0 m output cord and the red/green two-LED pair are common to every model, while each charger is still chosen by its own ceiling and current for the battery it serves.
Ordering against a battery, not a class
The order line for a charger in this class should name the battery it will serve — its ceiling, its charge limit, its connector — and not merely the class, because the class contains two ceilings (54.6V and 57.6V) that must never be crossed. The documentation that travels with the order is equally specific: the model's rated wattage for the depot's circuit plan, the efficiency figure for its running cost, and the cord and socket standards for its shelf. Programmes buying for a fleet should ask for the spare-unit price in the same message; a charger is a small component in the system and the one whose absence idles a vehicle, which makes the spare a line worth pricing on the quotation.