English

Home › Family › 60V & 72V Lithium Battery Chargers

Charger family — 60V/72V class

60V & 72V Lithium Battery Chargers

Two aluminium-shell models at the top of the line: a 67.2V 10A unit for the 60V class and an 84.0V 10A unit for the 72V class. Both are 10A models; the class is defined by its ceilings, not by a current ladder.

Illustration of a battery charger with two indicator lights and a cable

Key data — 60V & 72V Lithium Battery Chargers

ShellAluminium (both models)
Outputs67.2V 10A (672W); 84.0V 10A (840W)
Series fields (aluminium)220Vac input in selected models; ≥85% efficiency; red/green LED; 1.5m input cord, 1.0m output cord

The 60V/72V class models

67.2V 10A — aluminium67.2V±0.2; 10A±10%; 672W; 230×135×70mm; 3.0kg
84.0V 10A — aluminium84.0V±0.2; 10A±10%; 840W; 230×135×70mm; 3.0kg

Reading the 60V/72V class table

The pairings in this class are made on the battery side. The 72V 50Ah low-temperature pack carries a standard charge of 10A and a maximum of 20A across an 84.0–40.0V working range — the 84.0V 10A model in this class matches its ceiling and its standard rate, and at that rate the 50Ah pack's bulk charge takes about five hours. The 60V low-temperature pack has a 67.2–40.0V working range, which is the 67.2V model's ceiling; that pack's own charge limits are confirmed against its model table at enquiry. The two-wheeler series carries its own per-model ranges (the 72V example row tops out at 84.0V), so series pairings are confirmed per model rather than assumed from the class label. Both models share the aluminium series fields: 220Vac input in selected models, efficiency of 85% or better at rated load, red/green charge indication, IEC-standard input socket, 1.5m input and 1.0m output cords, and the same 230×135×70mm, 3.0kg case — the largest case in the aluminium line, shared by the two highest ceilings and by the 864W 48V-class model.

Specifying a 60V/72V charger enquiry

State the pack model and its charge ceiling and charge limits; at these voltages the ceiling check is the whole pairing decision. Fleets should size charger count from the roughly five-hour standard-rate charge of the 72V 50Ah pack and the rotation pattern, and should state the charge-point temperature where low-temperature packs are involved: the pack's charge window is −10~45°C, so the charger lives in the warm part of the depot even when the vehicle works outside it.

Which batteries these ceilings serve

Two ceilings, and the packs whose range tops they meet. The 67.2V 10A model (672W) serves the 60V class: the low-temperature family's 60V 25Ah pack, whose working range tops at exactly 67.2V. The 60V two-wheeler series takes a different ceiling — its 60V example's range tops at 71.4V, which neither model here outputs — so its charging is selected against that pack ceiling at enquiry. The 84.0V 10A model (840W) serves the 72V class: the 72V 50Ah low-temperature pack, whose working range tops at 84.0V and whose standard charge current is 10A, and the 72V two-wheeler series, whose 72V example's range tops at 84.0V. Both models are aluminium-series units with the family's shared fields: ≥85% efficiency at rated load, red/green two-LED indication, IEC input socket, 1.5 m power cord, 1.0 m output cord. In a mixed 60V/72V depot, the ceilings differ by 16.8V and the plugs do not care — label the charge points by ceiling.

Depot arithmetic at the top of the range

These are the catalogue's highest-voltage chargers. One 84.0V point at 840W nameplate and 85%-or-better efficiency draws under a kilowatt from the wall; a six-vehicle winter fleet on six points is a 6kW conversation — a dedicated circuit, planned once. Turnaround follows the same division as everywhere: the 72V 50Ah pack's 50Ah at 10A is about five hours of bulk charging, an overnight pattern with the morning's vehicles rotated first. For the 60V class, the 67.2V model's 10A is the charger's rating, not the pack's — the pairing, and the rate the pack accepts, are confirmed at enquiry against the model. The selection between the two classes is therefore not a charger decision at all — it is the battery decision (60V or 72V pack) arriving at the depot, and buyers should make it there, with the vehicle's load profile, rather than letting a charger purchase pre-empt it.

Why only two models

Every other class in this line offers a ladder of currents; this one offers two models, one per ceiling. The 72V 50Ah pack's own charge pair is 10A standard and 20A maximum: the 84.0V 10A model serves the standard rate, and a programme that wants charging toward the 20A maximum goes through the custom route, with the battery's limit as the brief — not through a bigger catalogue charger applied hopefully. The battery's figure governs at the top of the voltage range exactly as it does at the bottom: pick the ceiling from the pack, then the current from the pack's charge limit.

Commissioning the two ceilings

Commissioning a high-voltage charge point is a short ceremony with a long memory: verify the charger's ceiling against the battery's range top (67.2V or 84.0V, never assumed from the vehicle class), run the first charge supervised at the standard rate, and record the pairing — charger model, battery model, date — on the depot's charge-point label. The record matters because these are the catalogue's highest-voltage chargers and its least numerous; a point commissioned for the 72V 50Ah pack will still be there, labelled or not, when a 60V vehicle joins the fleet. The two models' shared series furniture — IEC socket, LED pair, standard cords — makes the physical installation routine; the labelling is the part that is safety equipment.