14.8V 10Ah Polymer Battery Pack

A 14.8V 10Ah polymer lithium battery pack for wireless monitoring, communications, medical devices, instruments and LED lighting: a light pouch-format unit of about 930g, with over-charge protection at 16.8V and over-discharge protection at 12.0V, a maximum charge current of 2A and continuous discharge of ≤3A. OEM and ODM builds are welcomed.

Illustration of a rounded purple battery pack with two terminals

Key data — 14.8V 10Ah Polymer Battery Pack

Nominal voltage / capacity14.8V / 10Ah
Maximum charge current2A (adjustable)
Continuous discharge≤3A
Pulse discharge≤15A
Cycle life500 cycles
Over-charge protection16.8V ±0.05V
Over-discharge protection12.0V ±0.25V
Dimensions / weight28×160×90mm / ≈930g

14.8V 10Ah ratings in full

Maximum charge current is 2A, adjustable. Continuous discharge is ≤3A with a ≤15A pulse. Cycle life is 500 cycles. The pack measures 28×160×90mm and weighs about 930g.

The 14.8V 10Ah specification

Read this table the way device builders read it. The discharge pair — ≤3A continuous, ≤15A pulse — describes a standby-and-burst instrument battery, not a traction battery: monitoring nodes, medical devices and lighting controllers draw modest continuous current and take their peaks in transmission or actuation bursts, and the five-to-one pulse ratio is sized for exactly that profile. The charge ceiling is 2A maximum and adjustable, so the charge source can be set below the ceiling for gentler duty. The protection lines run as voltages with tolerances — over-charge protection at 16.8V±0.05V, over-discharge at 12.0V±0.25V — which lets a device designer verify the pack's protection window against the equipment's own input range before the first prototype, instead of discovering it in test. Nominal energy is about 148Wh in a 930g pouch-format pack: the format's reason to exist is that it fits the flat cavities instruments and luminaires actually have.

Where the 14.8V 10Ah pack fits

The model's application list: wireless monitoring, communications equipment, medical devices, instruments and meters, LED lighting, traffic signs, small household appliances, power tools and toys. The common thread is equipment that is carried, mounted or installed rather than driven — devices whose battery is chosen by cavity dimensions and standby profile first, and by current second. OEM and ODM builds are welcomed, which is the route for a device maker whose cavity is close to, but not exactly, the 28×160×90mm envelope: the electrical platform (14.8V class, the protection thresholds, the 2A adjustable charge) is the starting point the custom build is quoted against.

Specifying a 14.8V polymer enquiry

Four facts specify this pack or its custom derivative. The cavity: length, width and the depth the pouch format must fit, checked against 28×160×90mm. The draw profile: continuous current against the ≤3A line and burst current against the ≤15A pulse, with burst duration. The charging supply — its current against the 2A adjustable ceiling. And the protection window: the equipment's own tolerances read against the 16.8V / 12.0V protection voltages. Send those four and the answer is a configuration — this model, or an OEM/ODM derivative quoted from its platform — rather than a correspondence. Buyers whose duty is daily deep cycling should also weigh the cycle figures model by model: this pack's own rating is 500 cycles, and the 12V 100Ah polymer pack's own rating is 500 cycles; the LiFePO4 families exist for the duties that spend cycles faster.

Applications, walked one by one

The application list — wireless monitoring, medical devices, lighting equipment and instruments — shares one shape: equipment that is carried, mounted or worn rather than driven, where a 930g flat pack earns its place by disappearing into the product. Monitoring: a camera or sensor head that draws watts, not tens of watts — at a 2W standby draw the pack's 148Wh is about three days in reserve, and at a 10W active draw about fifteen hours, both far inside the ≤3A continuous line. Medical devices: portable diagnostics and monitors, where the protection thresholds — over-charge and over-discharge voltages stated with tolerances — are part of the device maker's own safety file. Lighting: portable and emergency luminaires sized against the ≤3A continuous / ≤15A pulse pair. Instruments: measurement equipment whose draw is small and whose runtime is the working day. Each duty asks a different question of the same table, and the enquiry that names its duty gets its question answered first.

Living with a 500-cycle rating

Five hundred cycles is a planning number, not a warning. The rating is a count, spent one cycle at a time at whatever rate the equipment's duty sets — quickly in a device cycled daily, slowly in the instrument and monitoring pattern this pack is built for, where cycling is weekly or less. The operating levers that protect the count are the ones the protection lines describe: charge at or under the 2A ceiling, with gentler rates kinder than maximum rates; discharge inside the ≤3A continuous rating, treating the ≤15A pulse as a peak ceiling rather than a running rate; store the pack part-charged rather than full or empty when the equipment stands idle. A device programme that budgets the pack as a service item — the spare-pack line carried in the quotation from the start, spent when the count is — has understood the rating correctly.

Request a quote

Send the model or your target specification — voltage, capacity, discharge current and envelope.