Home › Family › 51.2V 100Ah Wall-Mounted Energy Storage Battery
Energy storage family — model page
51.2V 100Ah Wall-Mounted Energy Storage Battery
The anchor model of the storage family: a 51.2V 100Ah LiFePO4 unit built from 3.2V 100Ah cells in a 16S1P arrangement, rated at 5.12kWh with a 100A continuous discharge and ≥6000 cycles at 90% depth of discharge. It carries RS485, CAN and RS232 communication and parallels to 16 units for larger home and commercial storage.
Key data — 51.2V 100Ah Wall-Mounted Storage Battery (5.12kWh)
| Nominal voltage / capacity | 51.2V (16S) / 100Ah |
|---|---|
| Energy | 5.12kWh |
| Cells | 3.2V 100Ah cells, 16S1P |
| Working range | 57.6–44.8V |
| Charge current | 50A standard / 100A maximum |
| Discharge current | 100A continuous / 120A maximum (≤3 min) |
| Maximum load | ≤5kW |
| Internal resistance | ≤80mΩ |
| Communication | RS485 + CAN + RS232 (RJ45) |
| Parallel | Up to 16 units |
| Discharge temperature | −20~60°C |
| Cycle life | ≥6000 cycles (0.5C, 90% DOD, ≥80% capacity retained) |
| Dimensions / weight | 145×360×530mm / ≈43kg |
| Rating / cooling | IP20; natural cooling |
| Warranty | 36 months |
51.2V 100Ah ratings in full
Discharge is 100A continuous with a 120A maximum for up to three minutes, against a maximum load of 5kW. Charge is 50A standard and 100A maximum across a 57.6–44.8V working range. The unit measures 145×360×530mm and weighs about 43kg, with an IP20 rating and natural cooling.
The 51.2V 100Ah specification
Sixteen 3.2V 100Ah cells in series (16S1P) give the 51.2V nominal and 100Ah — 5.12kWh of nameplate energy. The working range runs from 57.6V at full charge down to 44.8V, and the inverter or charger paired with the unit must be set inside that window: the top of the range, 57.6V, is the charge ceiling. Internal resistance is ≤80mΩ. The cycle rating is ≥6000 cycles at 0.5C and 90% depth of discharge with at least 80% capacity retained — plan on roughly 4.6kWh of usable energy per cycle at that rated depth, because the cycle life applies to exactly that duty. Communication is RS485, CAN and RS232 on RJ45, three protocols on one unit, which is what makes the parallel architecture below practical: the inverter talks to the bank, not to sixteen separate batteries. Discharge temperature is −20~60°C.
Parallel scaling, worked through
Up to 16 units in parallel. The arithmetic: two units give 10.24kWh nameplate, about 9.2kWh usable at the rated 90% depth. Four units give 20.48kWh. Sixteen units give 81.92kWh — beyond most houses, into small commercial territory, and about 688kg of battery, a floor-standing installation long before the electrical limit arrives. The point of the architecture is that the decision is reversible: start at one or two units against a measured load, add modules in the same format when the load grows, and the communication platform does not change. The warranty period for the model is 36 months.
The 51.2V unit against the 12.8V 200Ah battery
Buyers cross-shopping the catalogue's two storage anchors should compare the two directly. Energy: 5.12kWh (this unit) against 2.56kWh. Cycle life: ≥6000 cycles at a stated 90% depth and 0.5C rate, against 3000+. Current: 100A continuous at 51.2V against 200A at 12.8V — the 51.2V unit delivers twice the throughput at four times the voltage and half the current, which means thinner cabling and lower connection losses on the storage side. Communication: RS485 / CAN / RS232 here, Bluetooth and RS-485 options there. The 12.8V model is a vehicle-and-bank battery that can store; this unit is a storage system, and the specification tables say so in numbers.
Installing and commissioning the wall unit
The panel converts to roughly 5.7 × 14.2 × 20.9 inches, and at about 43kg (roughly 95 lb) it is a two-person lift onto fixings rated for the unit plus bracket with margin, into structure, not plasterboard. The rating is IP20 with natural cooling: an indoor unit, sited where air can move around it. The communications ports (RS485, CAN, RS232) need their runs planned alongside the power cabling, separated enough to keep data clean. Commissioning is a sequence, not a switch: set the inverter's charge ceiling inside the unit's 57.6V top of range and its low-voltage behaviour to the 44.8V bottom, connect communications and confirm the inverter reads the bank's state of charge, then run a first controlled discharge and record delivered energy — the commissioning record every later capacity question refers back to.
Parallel banks commission per unit first (each unit charged, rested and voltage-checked individually) and combine second; a bank is only as honest as its weakest unit's first day. Seasonal checks are light: terminal tightness, comms heartbeat, and a capacity spot-check against the commissioning baseline. The 6000-cycle rating is consumed by depth more than by count, so the operating habit that protects the investment is keeping routine cycling inside the rated 90% depth the figure is rated at.
Worked example: a four-person house, evening shift
Metered evening consumption for a four-person house shifting load off peak: lighting and electronics 0.8kWh, refrigeration 0.6kWh, cooking 2.0kWh, laundry 0.8kWh — 4.2kWh between 17:00 and 23:00, with a peak draw of about 2.2kW when cooking and laundry coincide. Against one unit: 4.2kWh fits inside the 4.6kWh usable-at-90% figure, and 2.2kW sits well under the unit's 5kW maximum load — one unit covers the brief, with no margin for a bad day. Against two units in parallel: 9.2kWh usable covers the same evening plus an outage's essentials overnight, and the second unit is the same model on the same wall pattern. That is the sizing conversation this model is built for: one unit is a tariff decision, two are a resilience decision, and the figures price both. Enquiry questions: inverter compatibility against the 57.6V ceiling and the three communication protocols, wall-fixing specification for 43kg, and parallel-kit configuration.
Adding further units later
The parallel architecture makes expansion a mechanical exercise rather than a redesign, up to the ceiling of 16 units. Practical sequence: units join at matched state of charge, communication addressing is set per unit (the RS485 / RS232 / CAN options exist for exactly this), and the inverter's charge current is re-verified against the bank — a single unit takes 50A standard charge, and a bank configured for one unit simply charges more slowly rather than wrongly. The enquiry for an expansion order should state the installed units' age and cycle history: paralleling a new unit against a heavily-cycled one is electrically permissible within the architecture, but the bank's behaviour is set by its weakest member, and the honest recommendation is sometimes a fresh bank for the new duty with the old unit moved to a lighter circuit.
Pairing the inverter: ceiling, current and conversation
Three figures govern the inverter pairing. The ceiling: the unit's working range tops at 57.6V, so the inverter's charge voltage is set at or under 57.6V — a setting, not a charger class nickname. The current: the inverter's charge output should respect the 50A standard / 100A maximum pair, and its discharge demand the 100A continuous / 120A maximum pair against the 5kW maximum load; an inverter rated far beyond those figures is not a problem electrically, but its settings must be commissioned to the battery's numbers, not its own. The conversation: RS485, CAN and RS232 are all on the unit, so most inverter families can talk to it in one of their native dialects — confirm which protocol the chosen inverter will use, in writing, before the units ship, because a battery bank and an inverter that cannot exchange state of charge will still work, but blind: fixed voltage thresholds instead of real charge data, and shorter effective life as the price.
Siting an IP20 unit: the unglamorous paragraph that decides the warranty conversation
The unit is rated IP20 with natural cooling, and those two lines place it precisely: indoors, in a dry room, with air able to move around the case. A garage wall, a utility room, a plant-room corner — all suitable. An outdoor wall under an eave, a damp cellar, a sealed cabinet with no airflow — none of them are what IP20 and natural cooling describe, whatever the installation calendar prefers. Mounting arithmetic: about 43kg per unit on the wall fixings, so a three-unit wall is about 129kg plus brackets — check the wall construction before the second unit is ordered, or floor-stand the set from the start. The 36-month warranty is the manufacturer's commitment to the unit as specified; siting it as specified is the owner's half of the same document.
The discharge window: −20~60°C and what it asks of the room
The unit's discharge temperature range is −20~60°C — wide for an indoor product, and worth reading correctly. The bottom of the range covers the unheated-but-indoor spaces where storage actually lives: garages, outbuildings, plant rooms in cold climates. The top covers the same rooms in a hot summer, which is where natural cooling earns its mention on the table: a unit discharging at its 100A continuous rating in a 35°C room is shedding real heat, and the installation's clearance is what sheds it. Neither end of the range licenses outdoor siting — IP20 still governs the water question — but the range does answer the standing siting objection to wall batteries, which is the cold garage. If the room's winter temperature sits inside −20°C, the unit works there as specified; if it sits outside it, the room is the problem to fix, and it is cheaper to fix than the battery.
Resistance, and why ≤80mΩ is specified
The specification carries an internal-resistance line — ≤80mΩ — that most home buyers skip and most installers do not. Resistance is the figure behind voltage behaviour under load: at the unit's 100A continuous discharge, resistance is what separates the terminal voltage the inverter sees from the cell voltage behind it, and across a sixteen-unit bank it is part of why the units share current evenly rather than one unit working for sixteen. It is also the ageing witness: a bank whose resistance climbs is a bank whose capacity story is changing, and a baseline reading at commissioning is the cheapest diagnostic the owner will ever buy. The line is there because the installers this unit is built for ask for it; buyers comparing storage units should note which competing units omit it.